The thermometer is aligned with the middle of the forehead to measure body temperature (between the eyebrows above) and keep the vertical distance, press the Figure 2-Measuring position and distance When the ambient temperature of the thermometer changes too much, such as moving the Thermometer from one place of lower temperature to another place of higher temperature, Allow the thermometer to remain in a room for 30 minutes where thc temperature is between15C to 35 C 10 Note: Not intended 10 be sterilized. This. lpow thermometer user manualforensic science internships south africaforensic science internships south africa (4JContact the retailer or service center, This product can be set according to the subjects of different colors and different environments data to meet the different characteristics of populations or individuals Long press the MODE button to modify the measurement parameters 1) Unit Set-Fl Under the boot mode Long press SET button to enter FIT press the MODE or MEMO button to switch Celsius and Fahrenheit temperature units, press the SET button to confirm the unit settings (factory default ) 2} Fever alert set-F2 Under Fl state, press SET button to enter the F2, press the MODE button to decrease 0.1 C, press the MEMO button plus 0.1 C, long press to accelerate the speed of temperature regulation, and finally press the SET button to save. 1-5cm Figure 3 Align behind the ears to measurement General Setup and Use Start measuring 1.Turn on the thermometer by pressing the On/Scan button. The ambient temperature around the test person should be stable, should keep away from the larger flow fan, air-conditioning vents and so on. 3 Compare the reading of the digital thermometer to that of the independent thermometer. LPOW Thermometer Manual - Read online for free. 7-WARRANTY Our company warrants Non Contact Infrared Body Thermometer at the time of its original purchase and for the subsequence time period of one year. More Functions of digital thermometer HD LCD Screen Non Contact Measuring One Second Reading Body and Surface and Room Mode 50 Record Storage / Conversion Fever Alarm Voice On/Off The Non Contact Do you want to add products to your personal account? Battery Cover 3. Liquid crystal display (LCD)4. 50 Record Storage 5. Continue with Recommended Cookies, Home 1-800-Innovations Infrared Thermometer HTD-8813 Instruction Manual. Battery indicator6.Unit, Note: Not intended to be sterilized. such as moving the thermometer from one place of lower temperature to another place of higher temperature, allow the thermometer to remain in a room for 30 minutes where the temperature is between15 C to 35 C 6-DISPOSAL Used batteries should not be disposed of in the household rubbish. Wait for about thirty seconds and check that the thermometer reads 32F. Ensure that the bell icon, the symbol, and "BODY" is present on the thermometer's screen. The unit's optics sense emitted, reflected, and transmitted energy which is collect and focused onto a detector. Warnings alert the user to potential serious outcomes, such as injury or adverse events to the patient or user. 2. Always keep the thermometer within the storage temperature range 20 C to 55 C or 4 F to 131 F) and humidity range (s93% nun-condensing). 3. Wellbeing. These include: Oral: For this method, the thermometer is placed under the tongue. the tips of both thermometers are at the same depth. The manufacturer cannot be held liable for damage caused by incorrect application.The non contact infrared body thermometer is designed to minimize the possibility of hazards from errors in the software program by following sound and light engineering design processes, Risk Analysis and Software Validation. Comment * document.getElementById("comment").setAttribute("id","a792f2e8996f4772ecdccdd7701be7b1");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment. Wait at least 1 second for the next measurement. Simply warm your finger and reposition it so that it is right between the LED light and sensor. Get Price. Damage to the device resulting from misconnection with other devices. MOBI QUICK START User Instructions Model HTD8813C 70113 SN2004605520228 LOT 2535 The MOBI non-contact infrared body scan thermometer is a hand-held medical device intended for the quick measurement of body temperature (forehead) without touching the patient. Indicator of measurement result4.Speaker5. The Reason Choose Thermometer Gun This digital non contact thermometer have high precision sensor, accurate infrared temperature measuring element, which can measures the human body or an object temperature based on the infrared energy emitted by the forehead or an object (such as milk and water). Your email address will not be published. Dont open or repair the device by yourself. It is designed to be both accurate and fast. info@oyadvertising.com; 415-894-7649; 2013 honda accord air filter fram. Subjects sit qvietly 5-10 minutes before the test. 88. This equipment needs to be installed and put into service in accordance with the information provided in the ACCOMPANYING DOCUMENTS; This product needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided, and this unit can be affected by portable and mobile RF communications equipment. This product is not waterproof, do not be immersed in water or other liquid; If cleaning and disinfection, please follow the Care and Storage section requirements. In body made 34.0 t-35-1 C with green backlight- SIBS ICM-5CMtO.4-2inJ 50 ISV (PiAAl alkaline batteryX2 (IEC Type LR03) OperatinR Relative HumiditYSBS% atmospheric pressure:70Kpa-106Kpa Storage Temperature-20C-+550C / -4 Relative Humiditys93% atmospheric pressure-.70 106Kpa Dimension and Weighting Weight (without batteries) Compliance Item Equipment classification Type of protection Degree Of protection Front panel and case labeling Temperature I-lome healthcare environment gog L:13gmm X W: 95mm X Compliant with safety Standards: EN 2006.11122013, EN 60601-1-2:2007 Internally powered equipment Ion battery power) Non Applied part EN EN EN 60601-1-112010 Calculated values of the indicators according to ISO 80601-2-56 Indicators Clinical bias,z:. Calibration needed to ensure proper function for every two years or after device impact. If a cold compress on the forehead fever patients, or take other measures to coo] down, the temperature data will be low, should be avoided in this case to measure body temperature. Wait at least 1 second for the next measurement. See figure 3. The IR sensor can output different signal when measuring different object temperature or in different ambient temperature, and the ASIC can turn the signal from IR Sensor to a digital value and display it on the LCD. more. L211 . Dispatched with Royal Mail 2nd Class. During last measurement show, press and hold on On/Scan button to enter unit switch display. Measure the body's temperature hassle-free without touching the forehead with a non-contact infrared thermometer from He-Taida. Memory IP22 The first number 2; Protected against solid foreign objects Of 12 G rnrtt it and greater The second number: Protected against vertically falling water drops when enclosure titled, ****** Page 3 ****** Technical Specifications Measurement Unit Operating mode Measuring site Reference Body Site Rated output range Extended ouvput range Range Accuracy Disflay Resolution ftreecolor Ilacklight (Color Alarm) Auto Power OIT Time Measuring Time Measuring Distance Memories Power Supply Requirements Batteries Adaptable Range Environmental Operating Condition Transport and Storage Condition Adjusted modetEo.dy mo.dej Direct mode(surfact model Forehead Axillary dodymode; 35.OC 42.0 C/95.oF -107.601? 1)Pull the battery downward, toward the bottom of the Non Contact Infrared Body Thermometer, and remove the battery access door; 2)Insert two pieces AAA size batteries according to the + and 3jClose the battery cover. User Manual. The continuous use of a damaged unit may cause injury, improper results, or serious danger; Based on the current science and technology, other potential allergic reactions are unknown. At the end of its life, the appliance should not be disposed of in household rubbish. And theGreen means ready for next measurement. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. IDOIT Forehead Thermometer Adults, Digital Infrared Thermometer with Fever Alarm Memory Function Instant Accurate Reading, Non Contact thermometers for Baby Kids Adults. A digital thermometer can be used three different ways. 1s Measurement 2. When people moving from one place of lower temperature to another place of higher temperature, should at least remain in the test environment more than 5 minutes, to be consistent with the ambient temperature after the re-measurement. For increased ease and accuracy the laser pointer makes aiming even more precise. Read The User Instructions Carefully Symbol Of ''Type Bf Applied Parts'' 0598 Compliance With The Medical Directive 93/42/Eec For Medical Devices European Representative Lot Production Batch. LPOW Thermometer Manual. It may affect the accuracy of measurements when the forehead is covered by hair, perspiration, cap or scarf. Ifthe continuous measurement of five times, it is recommended to wait at least 30 seconds and then continue measurement, You cannot use thc thermometer in place where the sun is strong. An example of data being processed may be a unique identifier stored in a cookie. Body and Subject Mode 3 Colors Show Different Temperature 1. Description of Non Contact Infrared Body Thermometer Device principle and introduction Lightly slide the thermometer across the fore-head keeping the sensor flat and in contact with the skin until you reach the hairline, release the On/Scan button and remove the thermometer from the head, then the temperature will display on the screen. Data indicator3. * http://gbe.st/M8IKb6 [[ Apr 15 - Apr 23 ]]Gearbest's YouTube Channel GIVEA. 0. The Non-contact Infrared Body Thermometer, Model: HTD8823US, is an electronic clinical thermometer using an infrared sensor to detect body temperature from the forehead in people of all ages for home setting use. Ifyou have any problems with this device, such as setting up, maintaining or using. food and other temperature please select surface mode. Under F3 state , short press the SET button to enter F4, press the MEMO button to plus 0.1 C, press the MODE button decrease 0.1 C, long press fast subtraction temperature, and then SET button to confirm the parameter setting. Please report to us if any unexpected operation or events occur; 3. Related PostsNon-Contact Infrared Body Thermometer HTD8813CView FullscreenCatalogueSafety Informationif(typeof ez_ad_units!='undefined'){ez_ad_units.push([[970,90],'manuals_plus-large-mobile-banner-1','ezslot_2',115,'0','0'])};__ez_fad_position('div-gpt-ad-manuals_plus-large-mobile-banner-1-0');31- Overview5if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'manuals_plus-large-mobile-banner-2','ezslot_4',116,'0','0'])};__ez_fad_position('div-gpt-ad-manuals_plus-large-mobile-banner-2-0');if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'manuals_plus-large-mobile-banner-2','ezslot_5',116,'0','1'])};__ez_fad_position('div-gpt-ad-manuals_plus-large-mobile-banner-2-0_1');if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'manuals_plus-large-mobile-banner-2','ezslot_6',116,'0','2'])};__ez_fad_position('div-gpt-ad-manuals_plus-large-mobile-banner-2-0_2');.large-mobile-banner-2-multi-116{border:none!important;display:block!important;float:none!important;line-height:0;margin-bottom:2px!important;margin-left:auto!important;margin-right:auto!important;margin-top:2px!important;max-width:100%!important;min-height:250px;min-width:300px;padding:0;text-align:center!important}2- Operation103-Trouble shootingif(typeof ez_ad_units!='undefined'){ez_ad_units.push([[250,250],'manuals_plus-leader-2','ezslot_7',117,'0','0'])};__ez_fad_position('div-gpt-ad-manuals_plus-leader-2-0');144-Replacing the Battery155-Cleaning, Care and Storage166-Disposal167-Warranty178-Calibration18if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'manuals_plus-box-4','ezslot_8',103,'0','0'])};__ez_fad_position('div-gpt-ad-manuals_plus-box-4-0');if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'manuals_plus-box-4','ezslot_9',103,'0','1'])};__ez_fad_position('div-gpt-ad-manuals_plus-box-4-0_1');if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'manuals_plus-box-4','ezslot_10',103,'0','2'])};__ez_fad_position('div-gpt-ad-manuals_plus-box-4-0_2');.box-4-multi-103{border:none!important;display:block!important;float:none!important;line-height:0;margin-bottom:2px!important;margin-left:auto!important;margin-right:auto!important;margin-top:2px!important;max-width:100%!important;min-height:250px;min-width:300px;padding:0;text-align:center!important}()Documents / ResourcesLPOW Non-Contact Infrared Body Thermometer HTD8813C [pdf] User ManualLPOW, HTD8813C, Non-Contact, Infrared, Body, ThermometerRelated PostsThermometers D380 Non Contact Infrared Thermometer User ManualThermometers D380 Non Contact Infrared Thermometer General Description Non-contact Body Infrared Thermometer is Specially designed for take theproactive Non-Contact Infrared Thermometer 40010 Instruction ManualNon-Contact Infrared Thermometer 40010 Body Body Body Bodyhomewell ESSENTIALS Non-Contact Infrared Thermometer Instruction ManualNon-Contact Infrared ThermometerVERIDIAN JXB-311 Non-Contact Infrared Thermometer User GuideNon-Contact Infrared Thermometer Model JXB-311 / Ref No 09-313 These brief instructions allow you to quickly begin usingNovember 12, 2021November 20, 2021Posted inLPOWTags: _pdf, Body, HTD8813C, Infrared, LPOW, Non-Contact, ThermometerPost navigationNext Post Next post:LPOW A340 Fingertip Pulse Oximeter Instruction Manual, Thermometers D380 Non Contact Infrared Thermometer General Description Non-contact Body Infrared Thermometer is Specially designed for take the, Non-Contact Infrared Thermometer 40010 Body Body Body Body, Non-Contact Infrared Thermometer Model JXB-311 / Ref No 09-313 These brief instructions allow you to quickly begin using, Your email address will not be published. For a higher-tech option, we like the smart features available . Do not use solvents or immerse the device into water or other liquids. Heavy Duty Thermometer Infrared Forehead High Caliber Sensor No Contact with LCD Display for Medical Offices, Hospitals. LPOW official website offers everyone the highest quality and most affordable health and personal care products. . This equipment needs to be installed and put into service in accordance with the information provided in the ACCOMPANYING DOCUMENTS. The Ncm Contact [nfiared Bcnly Iheanometet is intendtal for use in an electromagnetic etwironnu:mt in wd)ich l.adiated RF am cvntrollecL Ille customer or user of the NOTI Contact Inframd Body can help prevent electromagnetic interference by maintaining a minimum distance lurween portable and nu)bih RF communiLations equipment (transmitters) and the Non Contact Infrared Body Thermometer as teommended lwlc.m acnding to maxinvurn cmtput power of the cullLipnaent. Rapidly measures body temperature to detect fevers and track temperature fluctuations in infants, children, and adults. Advanced features include temperature alarm, adjustable emissivity, data Hold, Min/Max readings, and auto power-off. Genkent Non Contact Infrared Thermometer - Forehead No Touch Thermometer - Digital Thermometer for Kids and Adults. Caution: this machine should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary, this machine should be observed to verify normal operation in the configuration in which it will be used. The operation principle is based on Infrared Sensor technology. Slide the battery cover back in until it snaps in place. Only use recommended batteries. Thanks in advance G. Ledtje, Guten Tag, bitte senden Sie mir eine Bedienungsanleitung in DEUTSCH des Artikels Ankovo HTD 8813 ansonsten bin ich gezwungen, diesen Artikel zurckzusenden, da ich keine Englischkenntnisse habe!!!!!!!! Remove the batteries and replace with 2 new one, type AAA, Make sure align properly as indicated inside the battery compartment. 4. The digital display is . 13 4-REPLACING THE BATTERY Open and release battery cover following indicator on the surface of battery cover. Since the human body temperature fluctuates all the time, the final temperature will also vary with the deviation of the measurement position during measurement. Pulse Oximeter. Immediate reading from the thermometer with mute / non-mute mode.It is a good thermometer for baby measurements at night. Free shipping on all US orders ! See all 29 - All listings for this product. It features an energy-saving automatic shut off function, and displays temperature in both Celsius and Fahrenheit. and are easily switchable. Unit Set ( Only applicable for HTD8823US). The patient can measure and change battery. (Figure 6). The customer or the user of Non Contact Infrared Body Thermometer should assure that itis used in such an environment. Warranty Policy. . Quick look. This product is designed to measure human body temperature on the forehead. 5) Exit setting mode In the F4 mode, press the SET button will automatically turn off the screen, exit setting. Used Batteries should be deposited at a collection point. 03, ****** Page 2 ****** Do not near strong electrostatic field or strong magnetic fields, thus avoiding the impact on the accuracy of the measurement data. It is. short interruptions and vuluge on power supply input lines Power frequency magnetic field IEC 61000-4-8 IEC 60601 test level Compliance level Electromagnetic environment guidanc 26 kV contact kV air Floors should be wood. When the ambient temperature of the thermometer changes too much. Observe the storage and operating conditions described in the Technical Specifications section.Not servicing/maintenance while the thermometer is in use.When using, shall not touch battery and the patient simultaneously.Do not use the device if it is damaged/ degraded/loosened in any way. 4.7 out of 5 Stars. If you have any doubt, please measure the temperature in other methods. Notice Purchase or possession of this device does not carry any express or implied license to use with replacement parts which would, alone or in combination with this device, fall within the scope of one of the relating patents. User Manual. Please read the manual first before using it, if not fully understand the usagest please stop using the thermometer. This product is designed to measure human body temperature on the forehead. The whole process takes 3~10 seconds. Dealers. It is very important to protect the lens from dirt and damage. Home LPOW LPOW Non-Contact Infrared Body Thermometer HTD8813C User Manualif((window.location.hostname.toLowerCase().indexOf('plus')<1)){window.location.href=window.location.replace(window.location.hostname,'manuals.plus');}if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[728,90],'manuals_plus-box-3','ezslot_3',102,'0','0'])};__ez_fad_position('div-gpt-ad-manuals_plus-box-3-0');Contents hide1 Be sure to read and understand all warnings listed of the instructions before use. body mode is used for measurmng human body temperature, the surface mode is used to measure the surface temperature, (The factory defult is body mode), Recalling and Erasing Memory Data The last temperature taken before the thermometer powers off is stored in memory up to 50. IR sensor2. Find the personal care product manual that you need at ManualsOnline. The device should be kept out of the reach of children/pets. In case, if system is latched up after changing battery. You will hear 3 beeps. LA Clinical repeatability. How to calibrate correctly. Mains power quality should he that of a typical commercial or hospital environment, If the user Of Lhe Non Contact Infrared Body Thermometer requires continued operation during power mains interruptions, it is recommended that the Nott Contact Infrared Body Thermometer be powered from an uninterruptible power supply or a battery, Power frequency magnetic fields should be at levels characteristic of a typical location in a typical omnmercial or hospital environment, Emission test RF emissions CISPR 11 RF CISPR 11 Harmonic enussions IEC 61000-3-2 Voltage fluctuations/ flicker emissions Compliance Group 1 Class B Not applicable Not applicable Electromagnetic environment guidance The Non Contact Infrared Body fierrnometer use RF energy only for its internal function. If this process didn't get rid of the Err error, there's a small chance the battery inside is a dud (it's rare, but . please follow the Care and Storage section requirements. Remove primary batteries if equipment is not likely to be used for long time, This product is not waterproof, do not be immersed in water or other liquid; If cleaning and disinfection. a. MBG User Manual. The 'Err' indication can be displayed on both the digital flexible tip thermometer and on the soother thermometer. This manual, accessories, Directions for Use, all precautionary information, and specifications should be read before use. This should reset the thermometer. b Over the frequency range 150 kliz to 80 MHz. This product must be operated in a stable environment, if the ambient environment was mutations, please Should be note whether there is fog on the sensor, if any, before using accordance with the Care and Storage section to removing the fog. SAFE AND HYGIENIC: Compared to mercury thermometer, there is no danger of breaking the glass or swallowing mercury. Apps. Date: 2020-07-07: LIP-ME204 Installation Instructions. B. Damage to the device resulting from accidents. $16. 299. press the MODE button to cycle conversion between body mode and surface mode. This method is used for adults and children 4 and over who are able to hold thermometer in mouth. Pulse Oximeter Health Monitor. Thermometer. Batteries and packaging are not covered under warranty When asked to provide warranty service, you must have a purchase date and purchase stamp dealers (including dealers name and address) of the warranty card. VIP. Required fields are marked *. Before changing the battery be sure the system is already power off. Plethysmograph - The SpO2 Waveform Each wave corresponds to a heartbeat and the amplitude to the amount of blood detected in your blood vessels. Open and release battery cover following indicator on the surface of shell. Parameter adjustment range -SC and +5C (factory default is O). Safety classification of ME EQUIPMENT Protection against electric shock Applied part Internally powered ME equipment Non Applied part Protection against harmful ingress of water or particulate matter [1322 Mode of operation Continuous operation 2- OPERATION 2.1 Battery installation Caution: The Non Contact Infrared Body Thermometer does not operate with dead batteries and does not input outer power. Published on 2017-04-07. Fill a glass with crushed ice. ChenE-mail: tomchen@hetaida.com.cnCompany Name: Wellkang LtdCompany Address: 16 Castle St, Dover, CT16 1PW, UKTel: +44 (20)30869438, 32876300Fax: +44(20)76811874Web: www.CEmark.com, www.CE-marking.com, www.CE-marking.eu,Email: AuthRep@CE-marking.euAbout this manual editionCurrent Updated Edition/Revision: A.1, April,13rd, 2020; This device may only be used for the purposes described in these instructions. Just take off battery, waiting 30 sec, then load battery again. Forehead scan method: position the probe flush (flat) on the center of the forehead, midway between the eyebrow and the hairline. Save $4.00 with coupon. Here are the most accurate infrared thermometers you can buy in 2023: Easy To Clean: iHealth No-Touch Forehead Thermometer. Features of the LPOW thermometer for adults When the ambient temperature of the digital thermometer changes too much, please allow the digital thermometer to remain in room for 30 minutes where the temperature is between 59-9515to 35. 11,871. We and our partners share information on your use of this website to help improve your experience. The LPOW Digital Infrared Thermometer has a high precision sensor that displays readings within one second. Warning Warnings are identified by the WARNING symbol shown above. X. Download List. . The lens is very delicate.It is very important to protect the lens from dirt and damage. determined an site surveys should hyss than the cornp]iart in each fhRluetuy Interference may occur in tiw vicinity of equipment marked the f&wing symbol; Rated maximum output power Of transtnilter[W) 0.1 1 10 150 ao 0.12 1.2 12 ao MHz to 800 MHz 0.12 0.38 12 12 0-23 0.73 2.3 7.3 23 NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. Remove the batteries if the thermometer is not to be used for a long period. $12. Remove the battery and replace with 2 new one, type AAA, Make sure align properly as indicated inside the battery cover . Press and hold the On/Scan button. The screen flickeri automatic turn off. / Conversion 4. High temperature Alarm 6. Turn on the thermometer by pressing the On/Scan button. Please take action to cool down or go for a doctor. Keithley 191 5.5 Digit Digital Multimeter ; 100 Master Mechanic Aluminum 1/8" Pop Rivets 1/4" max Grip ; 5pcs HSS 3/16*1/4*3/4*2-1/3 4 FLUTE END MILL Cutter CNC BIT Tool Set 1/4" Shank ; 1pc MCP2515 CAN bus module TJA1050 receiver SPI protocol ; Cobalt 41/64 X 1/2 Shank Silver & Deming Drill Bit S/Piont S&D LastCut 1PC H.S Press and hold the On/Scan button. Bag (0) 0. To calibrate the digital thermometer HoMedics Official Site - Massage, relaxation and wellness products . 2. When there, Thermometer Instructions for Use A. If you have any problems with this device, such as setting up, maintaining or using, please contact with SERVICE PERSONNEL of HeTaiDa Technology Co., Ltd. Dont open or repair the device by yourself. 4.6. Replace the battery cover. At iPrice Singapore, you can find the price list of the bestselling thermometers in the country. Calculated value -0.027 0.14 0.26 0.07 Note: the above value is calculated from clinical data of HTDBBIBD. Caution: this unit has been thoroughly tested and inspected to assure proper performance and operation! 352. It can be used on the forehead and ears, and the DMT can take a temperature in a speedy one to three seconds. Infrared Forehead Thermometer R1 399.00 R895.00 Loot.co.za 40% OFF. Make sure you are only putting the probe+wire in the oven, not the jack or transmitter. Name and model: medisana Infrared body thermometer TM A79 Model: HTD8813 Setting the measuring mode Display system: Digital display (LCD) When the device is running, pressing the MODE-button 6 to switch between body" mode Power supply: 3V , 2 x AAA-batteries 1.5 V Body mode: 34.0C-43.0C (93.2F-109.4F) and surface" mode. If abnormal perfortnanrn: iS observed. Ratings and Reviews. This product is intended in the home setting and primary care setting as screening tool. Please read this manual thoroughly before using the pulse oximeter! Rectal: For this method, the thermometer is inserted gently into the rectum. Your email address will not be published. Forehead Scan mode: gently position the probe flush (flat) on the center of the forehead, midway between the eyebrow and the hairline. Products outside the warranty expires, will be charged accordingly. Do not press any other buttons. 2nd (34,OC or Typical Measu:ed over the distance I S in). Multi-Mode Thermometer : The digital thermometer not only supporting forehead measure function, but also able to take room/object temperature. lpow digital thermometer htd8813 instructions - a portrait of the artist as filipino - a portrait of the artist as filipino - Changes performed by users without the prior written authorization of the company. 4} Overall temperature offset value-FO To meet the different colors, different characteristics of the population, or the environment caused by seasonal temperature change is large that need for temperature detection and debugging. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. 1 Second Instant Reading. (The factory default is the voice Prompt to open). Add a little clean water until the glass is full and stir. Slide the battery cover back in until it snaps in place. The measuring result of this product is only for your reference. Please make sure that the measurement distance is 0.4-2 inch, and the measurement position is the middle of the eyebrow. Immunity test Electrostatic discharge (ESP) IEC61000-40 Electrical fast transient/burst IEC 61000-44 Surge IEC V%ltage digxs. The Non-contact Infrared Body Thermometer, Model: HTD8823US, is an electronic clinical thermometer using an infrared sensor to detect body temperature from the forehead in people of all ages for home setting use. Do not dispose of used batteries in household waste. When asked to provide warranty service, please put the product to get our distribution points for repair. The warranty does not cover the followings; The device series number lbel is torn off or cannot be recognized. Do not use rechargeable batteries. Fast Reading: DISEN Non-Contact Thermometer. Documents / Resources3 If the meanned field strength in the location in which the Non Contact Infrared Body Thermometer is used exceeds the applicable RF compliance level above, the Non Contact Infrared Body Thermometer should be observed to verify normal operation.